The product complies with the harmonized standard EN 13163:2012.
TERMONIUM PLUS fasada EPS S EPS-EN 13163-T(1)-L(2)-W(2)-S(2)-P(5)-BS100-DS(N)2-DS(70,-)2 –TR100
Those are silvery and gray boards produced on the basis of innovative material refined, for example, by graphite, which after being added to the granules in the polystyrene production process, improves insulation features. Therefore, it is possible to obtain better thermal insulation results or the same ones with lower thickness. They are intended for thermal insulation of walls, including facades. The boards may be produced with flat or milled edges enabling proper fitting. The boards are manufactured in standard dimensions: 1000 mm long, 500 mm wide, 10 mm thick, and then every 10 mm.
Polystyrene subjected to voluntary certification and recommendation procedure at Building Research Institute (Polish: ITB), not resulting from the system of assessment and verification of performance constancy.
Declared properties of TERMONIUM PLUS fasada expanded polystyrene boards:
Dimension tolerance classes: | | |
thickness | T(1) | ± 1 mm |
length | L(2) | ± 2 mm |
width | W(2) | ± 2 mm |
rectangularity | S(2) | ± 2 mm/m |
flatness | P(5) | 5 mm |
Bending strength level | BS100 | ≥ 100 kPa |
Class of dimensional stability under constant normal laboratory
conditions | DS(N)2 | ± 0,2% |
Level of dimensional stability under specified temperature and humidity
conditions (temp. 70°C, 48 h) | DS(70,-)2 | 2% |
Tensile resistance to a force perpendicular to front surfaces | TR100 | ≥ 100 kPa |
Declared thermal conductivity ratio λD at a temperature of 10°C | 0,031 W/(m*K) |
Fire reaction class | E |
Declared value of thermal resistance RD depending on the thickness of TERMONIUM fasada boards
Thickness, mm | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
RD, m2K/W | 0,30 | 0,60 | 0,95 | 1,25 | 1,60 | 1,90 | 2,25 | 2,55 | 2,90 | 3,20 |
Thickness, mm | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 |
RD, m2K/W | 3,50 | 3,85 | 4,15 | 4,50 | 4,80 | 5,15 | 5,45 | 5,80 | 6,10 | 6,45 |
Implementation
The EPS foam boards should be used in accordance with the manufacturer’s instructions, RTQ ITB 1261/2013 Technical and Quality Recommendations, and guidelines included in a construction design. After having been fixed to an external wall, EPS boards should be immediately covered with an outer layer: reinforced layer and plaster of thermal insulation systems, facade panels in cavity walls, etc. Before fitting TERMONIUM PLUS fasada boards, sunlit facades should be covered with a protective net with the aim of protecting the EPS against the direct influence of weather conditions (UV radiation) which have a destructive effect on the EPS surface. TERMONIUM PLUS fasada boards should be protected against excessive heat (dark colour absorbs the sun’s rays). In case of a long-term exposure to atmospheric factors, the surface of boards can be covered with gray, thin covering. In this case, before a reinforced layer is applied by means of ETICS, remove the covering with fine sandpaper or a polisher until there are no loose particles weakening the adhesion to the polystyrene on the surface.
In order to fix TERMONIUM PLUS fasada boards, use TO-KPS polyurethane adhesive (together with mechanical fasteners) or TO-KS adhesive. To apply a reinforced layer, apply TO-KU universal adhesive or TO-KUB universal white adhesive and TO-S145 or TO-S170 mesh. TERMONIUM PLUS fasada boards adhered to facades should be protected against the direct contact with sunlight by using protective net during work and at least three days after its completion.
Caution
Do not use the EPS boards in direct contact with the substances having a destructive effect on polystyrene EPS, such as organic solvents (acetone, benzene, nitro), etc.
Package, storage, transportation
TERMONIUM PLUS fasada boards are supplied only in the original manufacturer's packaging. The label on a package contains the following information: the name of a product, the manufacturer's name and a factory name, the date of production, EN 13163:2012 standard number, a code compatible with that standard, and declared technical features. TERMONIUM PLUS fasada boards should be protected against damaging and weather conditions.